Loss of control
Japan
Published 31 Jul 2017
Ref JP-1140841
Isuzu: Wiring
Translated from Japanese · machine translation
- Country
- Japan
- Published
- 31 Jul 2017
- Units affected
- 1257
- Reference
- JP-1140841
Affected vehicles
Isuzu Erga 2015–2017
Isuzu Erga Mio 2015–2017
Hazard
On large and medium-sized transit buses, the protective edge finish at the connection between the distribution box below the driver's seat and the driver's side wall panel is inadequate, causing the edge to interfere with wiring in some cases. Continued use may result in wiring insulation damage and short-circuit, which in worst case could cause engine shutdown during operation and prevent restart.
Show original (日本語)
①大型・中型路線バスにおいて、運転者席下側配電箱と運転者席側壁パネルの接続部の端部の保護が不適切なため、当該端部と配線が干渉するものがある。そのため、そのまま使用を続けると、配線の被覆が損傷して短絡し、最悪の場合、走行中にエンジンが停止し、再始動できなくなるおそれがある。
Remedy
Inspect the connection between the distribution box below the driver's seat and the driver's side wall panel on all vehicles. Add protective material where edge protection is inadequate, and repair any damaged wiring.
Show original (日本語)
①全車両、運転者席下側配電箱と運転者席側壁パネルの接続部を点検し、端部の保護が不適切なものは保護材を追加するとともに、配線が損傷している場合は配線を補修する。