All recalls
Published 20 Apr 2017 Ref JP-1140403

Isuzu: Wiring

Translated from Japanese · machine translation

Country
Japan
Published
20 Apr 2017
Units affected
668
Reference
JP-1140403

Affected vehicles

Isuzu Erga 2015–2016 Isuzu Erga Mio 2015–2016

Hazard

In large and medium-sized route buses, wiring routing in the power distribution box located below the driver's seat is improper, causing wiring to be pinched during side panel installation. Continued use in this condition may result in damage to wire insulation, leading to short circuits, and in worst cases, preventing door opening and closing.
Show original (日本語)
大型・中型路線バスにおいて、 ③運転者席下側配電箱内の配線の配索が不適切なため、側面パネル取付け時に配線を挟み込んだものがある。そのため、そのまま使用を続けると、配線の被覆が損傷して短絡し、最悪の場合、扉の開閉ができなくなるおそれがある。

Remedy

All vehicles: Install protective wiring sheets on wiring near the side panel mounting area of the power distribution box below the driver's seat, and inspect wiring in this location. If damage is found, perform repairs.
Show original (日本語)
③全車両、運転者席下側配電箱の側面パネル取付け部付近の配線に配線保護シートを追加するとともに、当該部の配線を点検し、損傷している場合は補修する。