All recalls
Published 20 Apr 2017 Ref JP-1140411

Hino: Wiring

Translated from Japanese · machine translation

Country
Japan
Published
20 Apr 2017
Units affected
264
Reference
JP-1140411

Affected vehicles

Hino Hino Blue Ribbon 2015–2016 Hino Hino Blue Ribbon Hybrid 2015–2016

Hazard

In large-size route buses, improper routing of wiring within the power distribution box above the driver's seat causes interference between the wiring and the edges of the wire-securing bracket. Continued operation in this condition may result in damage to the wire insulation, causing a short circuit, and in the worst case, the doors may become unable to open or close.
Show original (日本語)
大型路線バスにおいて、 ①運転者席上側配電箱内の配線の配索が不適切なため、配線が固定用ブラケットの端部と干渉するものがある。そのため、そのまま使用を続けると、配線の被覆が損傷して短絡し、最悪の場合、扉が開閉できなくなるおそれがある。

Remedy

For all vehicles, add protective material to the wiring-securing bracket in the power distribution box above the driver's seat, and inspect the wiring in this area. If damage is found, repair the wiring.
Show original (日本語)
①全車両、運転者席上側配電箱内の配線固定用ブラケットに保護材を追加するとともに、当該部の配線を点検し、損傷している場合は配線を補修する。