Fire risk
Japan
Published 15 Oct 2014
Ref JP-1134490
Yamaha: Wiring
Translated from Japanese · machine translation
- Country
- Japan
- Published
- 15 Oct 2014
- Units affected
- 1818
- Reference
- JP-1134490
Affected vehicles
Yamaha MT-07 2014
Yamaha MT-07A 2014
Hazard
The electrical wiring connected to the battery positive terminal has improper length and the seat bracket has an inappropriate shape, allowing the electrical wiring to ride over the seat bracket and become pinched between the seat and bracket. Continued use in this state may damage the wiring insulation, causing a short circuit that could result in fire in the worst case.
Show original (日本語)
バッテリーのプラス端子に接続する電気配線の長さ及びシートブラケットの形状が不適切なため、電気配線がシートブラケットの上に乗り上げ、シートとシートブラケットの間に挟まることがある。そのため、そのままの状態で使用を続けると、当該電気配線の被覆が損傷し短絡して、最悪の場合、火災に至るおそれがある。
Remedy
Replace the electrical wiring connected to the battery positive terminal and seat bracket with corrected parts on all vehicles, and add a clamp to the electrical wiring. Additionally, replace the owner's manual with a corrected version.
Show original (日本語)
全車両、バッテリーのプラス端子に接続する電気配線及びシートブラケットを対策品に交換するとともに、電気配線にクランプを追加する。また、取扱説明書を修正したものに交換する。