Loss of control
Japan
Published 10 Aug 2023
Ref JP-1153650
Komatsu: Computer (Power Transmission)
Translated from Japanese · machine translation
- Country
- Japan
- Published
- 10 Aug 2023
- Units affected
- 39
- Reference
- JP-1153650
Affected vehicles
Komatsu WA470-10 2019–2023
Hazard
In the work equipment controller of the shovel loader, due to an improper program, if the power supply voltage drops during the self-diagnosis routine that automatically initiates after the key is turned ON, the self-diagnosis will not complete normally. Although normal travel and work operation can be performed in this state, if a transmission wiring short circuit coincidentally occurs during travel, the vehicle will make an emergency stop.
Show original (日本語)
ショベル・ローダの作業機コントローラにおいて、プログラムが不適切なため、キーON後に自動的に開始される自己故障診断中に電源電圧が低下すると、自己故障診断が正常に終了しない状態となる。 なお、この状態でも走行および作業は正常に行えるが、万が一走行中にトランスミッションの配線短絡を併発した場合、急停止する。
Remedy
For all vehicles, reprogram the work equipment controller with the corrected program version.
Show original (日本語)
全車両、作業機コントローラのプログラムを修正版プログラムに書き換える。