Fire risk Published 25 Sep 2012 Ref JP-1218710

Iseki: Wiring

Translated from Japanese · machine translation

Safety-critical recall — fire risk. If your vehicle is affected, contact your dealer before driving.
Country
Japan
Published
25 Sep 2012
Units affected
66
Reference
JP-1218710

Affected vehicles

ヰセキ T8125D 2008–2012 ヰセキ T8140D 2008–2012

Hazard

The power wiring between the engine starter terminal and battery is routed improperly, causing the wiring to become pinched in the gap between the vehicle frame and transmission case. If continued in this condition, the wiring insulation may be damaged, resulting in a short circuit. High current from the battery will flow through the isolator (power cutoff device), causing the wiring and isolator terminal to burn. In the worst case, this may lead to fire.
Show original (日本語)
原動機のスタータ端子とバッテリ間の電源配線の配索が不適切なため、当該配線が車体フレームとトランスミッションケースの隙間に挟まれているものがある。そのため、そのまま使用を続けると、当該配線のカバーが損傷して短絡をおこし、バッテリからの大電流がアイソレータ(電源遮断装置)に流れ、配線とアイソレータ端子部が焼損し、最悪の場合、火災に至るおそれがある。

Remedy

Reroute the power wiring and ground wiring on all vehicles and secure the ground wiring to the power wiring with harness bands.
Show original (日本語)
全車両、電源配線とアース配線の配索を変更し、ハーネスバンドでアース配線と結束する。

Official source

View the official recall notice