Published 28 Jun 2011 Ref JP-1127750

Yamaha: Wiring

Translated from Japanese · machine translation

Country
Japan
Published
28 Jun 2011
Units affected
14294
Reference
JP-1127750

Affected vehicles

Yamaha Majesty YP250 2007–2010

Hazard

The centralized ground joint connector (for grounding lighting fixtures such as headlamps and warning devices) has limited margin in the terminal connection allowable temperature. Heat generation from electrical current can cause the connector to melt and degrade. This results in poor electrical continuity, preventing proper grounding, which causes lighting fixtures such as headlamps and warning devices to malfunction.
Show original (日本語)
集中アース・ジョイントコネクタ(前照灯等の灯火器類及び警音器等のアース用)において、接続端子部の許容温度に余裕がないため、通電による発熱により当該コネクタが溶損するものがある。そのため、導通不良により、適切にアースされなくなると、前照灯等の灯火器類及び警音器が作動しなくなる。

Remedy

All vehicles: Inspect the connector. Replace the electrical wiring from the connector to a replacement product with a distributed headlamp ground line for connectors showing signs of melting and degradation. For connectors without damage, add a sub-harness to the headlamp ground line to divert current.
Show original (日本語)
全車両、当該コネクタを点検し、溶損しているものは、電気配線を当該コネクタから前照灯のアース線を分配した対策品と交換し、溶損していないものは、前照灯のアース線に電流を分流させるためのサブハーネスを追加する。