Japan
Published 29 Mar 2011
Ref JP-1127280
Mitsubishi: Exhaust Emission Reduction Device
Translated from Japanese · machine translation
- Country
- Japan
- Published
- 29 Mar 2011
- Units affected
- 220
- Reference
- JP-1127280
Affected vehicles
Mitsubishi Fuso 2009–2010
Hazard
Certain large trucks equipped with box-type mufflers have incorrect urea water dosing nozzles installed. Continued use in this condition may cause urea water to crystallize, potentially clogging the nozzle and muffler.
Show original (日本語)
箱形マフラーを装着した大型トラックの尿素水ドージングノズルにおいて、誤品を組み付けたものがある。そのため、そのままの状態で使用を続けると、尿素水が結晶化し、当該ノズルやマフラーが詰まるおそれがある。
Remedy
Inspect the nozzle on all vehicles and replace with the correct part if an incorrect nozzle is installed. If urea water crystal deposits are found in the muffler due to the incorrect nozzle installation, perform DPF manual regeneration to remove the crystals. If urea water crystals cannot be removed by DPF manual regeneration, replace the muffler with a new unit.
Show original (日本語)
全車両、当該ノズルを確認し、誤品が装着されている場合は、正規品に交換する。また、誤品の装着によってマフラー内に尿素水結晶の堆積が認められた場合は、DPF手動再生を行って尿素水結晶を除去する。なお、DPF手動再生を行っても尿素水結晶が除去されないものは、マフラーを新品に交換する。