Fire risk
Japan
Published 15 Apr 2008
Ref JP-1121040
Hino: Selega
Translated from Japanese · machine translation
- Country
- Japan
- Published
- 15 Apr 2008
- Units affected
- 1794
- Reference
- JP-1121040
Affected vehicles
Hino Hino Selega 2005–2008
Hazard
Inadequate waterproofing of the heating exchanger storage box allows moisture containing de-icing agent to enter, causing leakage current at the blower motor harness connector. Continued operation may cause the connector to overheat and potentially ignite.
Show original (日本語)
暖房用熱交換器の格納箱の防水構造が不適切なため、融雪剤を含んだ水分が侵入し、熱交換器の送風用モータのハーネスコネクタ部で漏電を起こす場合がある。そのため、そのまま使用を続けると、当該コネクタ部が発熱し、最悪の場合、ハーネスコネクタ部が発火するおそれがある。
Remedy
For all vehicles: apply sealant to the heating exchanger storage box, replace the blower motor harness connector and storage box drain outlet with corrected parts, and inspect the blower motor (replace if corroded). As a temporary measure pending parts availability, cut the harness connector and directly splice the harnesses.