All recalls
Brakes Published 3 Aug 2006 Ref JP-1117072

Isuzu: Parking Brake General

Translated from Japanese · machine translation

Safety-critical recall — brakes. If your vehicle is affected, contact your dealer before driving.
Country
Japan
Published
3 Aug 2006
Units affected
901
Reference
JP-1117072

Affected vehicles

Isuzu GIGA 2001–2003

Hazard

In spring-applied parking brake systems, the material of a portion (elbow fitting) of the piping connecting the spring chamber and service brake chamber is inappropriate. Deterioration over time causes cracks to develop, allowing water to enter the spring chamber, which can cause the spring to rust. This may lead to spring fracture and diaphragm damage, resulting in air leakage. In the worst case, the parking brake may engage while the vehicle is in motion. This is an additional recall notice for vehicles previously recalled under notification number 1689 dated June 29, 2006. Due to an error in the original vehicle selection, 2001-model tractors are being added as affected vehicles.
Show original (日本語)
スプリング式駐車制動装置において、スプリング室とサービスブレーキ室とを連結する配管の一部(エルボ部)の材質が不適切なため、経時劣化により亀裂が発生し、スプリング室に水が浸入し、スプリングが錆びることがある。そのため、スプリングが折損し、ダイヤフラムが損傷してエアが漏れ、最悪の場合、走行中駐車ブレーキが作動するおそれがある。 本件は、平成18年6月29日付け「届出番号1689」にてリコール届出を行ったものですが、対象車両の選定に誤りがあったため、対象車両(2001年式トラクタ)を追加し、新たに届出するものです。

Remedy

All vehicles: Replace the elbow fitting with corrected parts.
Show original (日本語)
全車両、エルボ部を対策品と交換する。

Official source

View the official recall notice