Japan
Published 6 Dec 2005
Ref JP-1115690
Mitsubishi: Electrical System (Other)
Translated from Japanese · machine translation
- Country
- Japan
- Published
- 6 Dec 2005
- Units affected
- 467
- Reference
- JP-1115690
Affected vehicles
Mitsubishi F13F 2003–2005
Mitsubishi F13FL 2003–2005
Mitsubishi F17D 2003–2005
Mitsubishi F17DL 2003–2005
Mitsubishi F25C 2003–2005
Mitsubishi F25CL 2003–2005
Mitsubishi F34 2003–2005
Mitsubishi F34L 2003–2005
Mitsubishi F35 2003–2005
Mitsubishi F35L 2003–2005
Mitsubishi KF2D 2003–2005
Mitsubishi KF3C 2003–2005
Mitsubishi KF4C 2003–2005
Mitsubishi SA-F16D 2003–2005
Mitsubishi SA-FKF6B 2003–2005
Mitsubishi SB-F14E 2003–2005
Mitsubishi SB-F18C 2003–2005
Mitsubishi SB-F37 2003–2005
Hazard
In vehicles with automatic transmissions, the meter panel circuit board is improperly designed. Repeated thermal expansion of the board due to internal temperature fluctuations causes cracks to develop at solder joints on resistive components. Continued use allows cracks to propagate, resulting in shift position information within the panel no longer updating when gear shifts occur. In the worst case, forward/reverse switching becomes impossible, and the vehicle may travel in a direction opposite to the selected shift position.
Show original (日本語)
自動変速機付車において、メーターパネルの基板が不適切なため、メーター内部の温度上昇による基板の熱膨張の繰返しにより、抵抗半田部に亀裂が生じるものがある。そのため、そのまま使用を続けると、亀裂が進行し、シフトチェンジしてもパネル内のシフト位置情報が更新されなくなり、最悪の場合、前後進の切り替えができず、シフト位置と逆方向に走行するおそれがある。
Remedy
Replace the meter panel with corrected parts on all vehicles.
Show original (日本語)
全車両、メーターパネルを対策品と交換する。