Fire risk
Japan
Published 27 Nov 2003
Ref JP-1110100
Isuzu: Other (Safety Lighting)
Translated from Japanese · machine translation
- Country
- Japan
- Published
- 27 Nov 2003
- Units affected
- 48078
- Reference
- JP-1110100
Affected vehicles
Isuzu GIGA 1996–2000
Hazard
The contact shape of the side marker light switch inside the combination switch is inappropriate. When the side marker lights are operated while the combination switch is held at mid-stroke during lane changes, arc discharge occurs between the contacts, causing contact wear. Wear debris accumulates on the circuit board, potentially causing a short circuit between contacts on the board, which generates heat and may result in fire.
Show original (日本語)
コンビネーションスイッチ内部の側方照射灯スイッチの接点形状が不適切なため、車線 を変更する際等、コンビネーションスイッチをそのストロークの中間位置に保持した状態 で側方照射灯を点灯させる操作を行なうと、当該接点間にアーク放電が発生して接点が摩 耗し、摩耗粉が基板上に堆積するものがある。そのため、基板上の接点間が短絡して発熱 し、火災に至るおそれがある。
Remedy
Inspect the side marker light switch operation on all vehicles and add a relay to the side marker light switch circuit.
Show original (日本語)
全車両、側方照射灯スイッチの作動を点検し、側方照射灯スイッチ回路にリレーを追加 する。