Fire risk
Japan
Published 23 Jul 2026
Ref JP-1158520
Sakai: ER555F — Other (control device)
Translated from Japanese · machine translation
- Country
- Japan
- Published
- 23 Jul 2026
- Units affected
- 145
- Reference
- JP-1158520
Affected vehicles
サカイ ER555F 2017–2023
Hazard
In the grader's brake solenoid valve, heat resistance evaluation of the coil against aging deterioration was insufficient during electrical circuit design. If heat damage accumulates during use, a partial short circuit may occur inside the coil, increasing current in the electrical wiring; in the worst case, the wiring may burn out, making the vehicle unable to travel.
Show original (日本語)
グレーダのブレーキ用電磁バルブにおいて、電気回路の設計時に当該バルブ内のコイルの経年劣化による耐熱性評価が不足している。そのため、使用過程で発熱によるダメージが蓄積すると、コイル内部で部分短絡が発生して電気配線の電流が増加し、最悪の場合、当該配線が焼損し走行不能となるおそれがある。
Remedy
On all vehicles, change the brake solenoid valve power supply wiring to a heat-resistant specification and add a fuse to the circuit. Also inspect the brake solenoid valves and replace any damaged ones with new ones.
Show original (日本語)
全車両、ブレーキ用電磁バルブの電源供給配線を耐熱仕様に変更し、回路内にヒューズを追加する。また、ブレーキ用電磁バルブを点検し、損傷しているものは新品に交換する。