All recalls
Published 17 Sep 2026 Ref JP-1158820

Honda: Super-ONE — Other (electric motor)

Translated from Japanese · machine translation

Country
Japan
Published
17 Sep 2026
Units affected
1
Reference
JP-1158820

Affected vehicles

Honda Super-ONE 2026

Hazard

In the motor control unit, due to an improper tightening method for the current-carrying plate mounting bolts inside the battery charger, some units have insufficient contact pressure between the current-carrying plate and the high-voltage terminal. If the current-carrying plate moves due to driving vibration, contact resistance at that part may increase and generate heat, causing poor continuity. This illuminates the power system warning light and activates control that stops drive motor output, potentially resulting in loss of propulsion.
Show original (日本語)
電動機用制御装置において、バッテリチャージャ内部の通電板取付けボルトの締付け方法が不適切なため、通電板と高電圧端子の密着力が不足しているものがある。そのため、走行振動等により通電板が動くと、当該部の接触抵抗が増加して発熱し、導通不良となり、パワーシステム警告灯が点灯するとともに、駆動用モータの出力を停止させる制御が働き、走行不能となるおそれがある。

Remedy

Replace the battery charger with a known-good unit.
Show original (日本語)
バッテリチャージャを良品と交換する。

Official source