Published 19 May 2025 Ref JP-1240030

BMW Alpina: Computer (Engine)

Translated from Japanese · machine translation

Country
Japan
Published
19 May 2025
Units affected
4
Reference
JP-1240030

Affected vehicles

BMW Alpina XB7 2023–2024

Hazard

The onboard diagnostic system's diagnostic program in the DME (electronic control unit that oversees the entire engine control system) has insufficient design consideration. When abnormalities related to the variable valve mechanism (Valvetronic) are detected, diagnostic information is not saved to memory and may be lost. Additionally, if failures in related components such as oxygen sensors are detected simultaneously, their diagnostic information is also lost and the warning light may not illuminate. As a result, when exhaust gas volume increases due to related component failures, this cannot be detected, and the vehicle may not comply with safety standards.
Show original (日本語)
DME(エンジン制御システム全体を統括する電子制御ユニット)の車載式故障診断装置の診断プログラムにおいて、設計検討が不十分なため、可変バルブ機構(バルブトロニック)関連の異常を検出した際に診断情報がメモリに保存されず、失われることがある。また、酸素センサー等の関連する部品の故障を同時に検出した場合、それらの診断情報も失われて警告灯が点灯しないおそれがある。そのため、関連部品の故障により排気ガスの量が増加した場合に検出できず、保安基準に適合しないおそれがある。

Remedy

Update the DME program in all vehicles. The program update is performed by connecting to a diagnostic device at an authorized dealer.
Show original (日本語)
全車両、DMEのプログラムを更新する。 なお、プログラムの更新は販売店に入庫し、診断機に接続することにより実施する。