Fire risk
Japan
Published 16 Apr 2025
Ref JP-1156440
Hino: Wiring
Translated from Japanese · machine translation
- Country
- Japan
- Published
- 16 Apr 2025
- Units affected
- 77485
- Reference
- JP-1156440
Affected vehicles
Hino Hino Ranger 2017–2022
Hazard
In the electrical wiring on the left side of the engine, insufficient design consideration of cable routing may cause the wiring to interfere with surrounding components such as the intercooler. Continued use in this condition may result in damage to the wiring insulation due to engine vibration, which in the worst case could lead to wiring short circuit and fire.
Show original (日本語)
エンジン左側の電気配線において、配索の設計検討が不十分なため、配線がインタークーラー等の周辺部品と干渉することがある。そのため、そのまま使用を続けると、エンジンの振動等で配線の被覆が損傷し、最悪の場合、配線の短絡により火災に至るおそれがある。
Remedy
All vehicles will have protective material added to the affected wiring, and some vehicles will have the wiring retention bracket replaced with a corrective part. Any damage found on the affected wiring will be repaired.
Show original (日本語)