Fire risk
Japan
Published 26 Sep 2024
Ref JP-1238820
Mercedes-Benz: Wiring
Translated from Japanese · machine translation
- Country
- Japan
- Published
- 26 Sep 2024
- Units affected
- 24
- Reference
- JP-1238820
Affected vehicles
Mercedes-Benz C200 2022
Mercedes-Benz C220d 2022
Hazard
In 12V and 48V ground wiring located in the engine compartment and undercarriage, improper assembly at manufacturing has resulted in cases where the nut at the body ground terminal point is not tightened to the specified torque. Due to vibration during driving, such nuts may loosen, causing increased electrical resistance and heat generation, which can melt surrounding components and potentially lead to fire.
Show original (日本語)
エンジンルーム内や床下の12V, 48Vアース配線において、製造時の組付けが不適切なため、ボディーアースのターミナルポイントにナットが規定トルクで締め付けられていないものがある。そのため、走行時の振動等で当該ナットが緩み電気抵抗が増加して、発熱することで周囲の部品が溶損し、最悪の場合、火災に至るおそれがある。
Remedy
Inspect all vehicles for looseness in 12V and 48V ground wiring nuts in the engine compartment and undercarriage. If looseness is found, inspect the contact surfaces of the ground wiring and nut, and re-tighten to the specified torque. If the contact surfaces show damage or melting is evident in surrounding areas, replace the relevant components with new parts.
Show original (日本語)
全車両、エンジンルーム内や床下の12V, 48Vアース配線のナットの緩みを点検する。緩みがある場合はアース配線やナットの接触面を点検し規定トルクで締め付けなおす。なお、接触面に損傷がある場合や、周囲に溶損がある場合は、関連する部品を新品に交換する。