Loss of control
Japan
Published 22 Apr 2021
Ref JP-1232090
Mercedes-Benz: Other (Electric Motor)
Translated from Japanese · machine translation
- Country
- Japan
- Published
- 22 Apr 2021
- Units affected
- 401
- Reference
- JP-1232090
Affected vehicles
Mercedes-Benz E350 de 2018–2020
Mercedes-Benz E350 e 2018–2020
Hazard
In hybrid vehicle high-voltage wiring, improper contact design of shielded conductors causes contact resistance to increase and exceed rated current during high-load operation or high motor-assist driving, resulting in insufficient shielding effectiveness. Electrical noise received by the motor control unit causes communication failure, which in worst case may result in engine shutdown during driving and loss of propulsion.
Show original (日本語)
ハイブリット車両の高電圧配線において、シールド線の接点の設計が不適切なため、高負荷運転等で電気モータのアシスト量が多い走行を行うと、接点の抵抗が増えて許容電流を超え、シールド効果が十分に得られないことがある。そのため、発生した電気的ノイズを電気モータ制御装置が受けることで通信障害を引き起こし、最悪の場合、走行中にエンジンが停止し、走行不能になるおそれがある。
Remedy
Replace high-voltage wiring with corrective parts on all vehicles.
Show original (日本語)
全車両、高電圧配線を対策品に交換する。