Fire risk
Japan
Published 16 Oct 2020
Ref JP-1148280
Hino: Selega
Translated from Japanese · machine translation
- Country
- Japan
- Published
- 16 Oct 2020
- Units affected
- 771
- Reference
- JP-1148280
Affected vehicles
Hino Hino Selega 2005–2020
Hazard
The metal water supply tank for lavatories on large buses has insufficient strength in the tank mounting bracket, which can cause damage to the bracket and result in tank detachment. This can damage the electrical wiring for the lavatory that is secured to the tank, potentially leading to fire.
Show original (日本語)
大型バスのトイレ用金属製給水タンクにおいて、タンク固定部の強度が不足しているため、固定部が損傷してタンクが脱落することがある。そのため、タンクに固定されているトイレ用電気配線が損傷して、火災に至るおそれがある。
Remedy
Due to time required to prepare improved water supply tank measures, the following interim measures shall be performed: 1. Inspect the water supply tank mounting bracket on all vehicles and provisionally secure it with a belt. If the tank has detached, replace it with a new tank. 2. Inspect all vehicles for damage to the lavatory electrical wiring and modify the mounting position and cable routing. If the wiring is damaged, repair it. Upon completion of improved water supply tank measures, the remedial method will be revised accordingly.
Show original (日本語)
給水タンクの改善措置準備に時間を要することから、以下の措置を行う。 1.全車両、給水タンク固定部を点検し、暫定的にベルトで固定する。 なお、タンクが脱落している場合には新品タンクに交換する。 2.全車両、トイレ用電気配線の損傷有無を点検し、固定位置と配索を変更する。 なお、配線が損傷している場合には補修する。 給水タンクの改善措置が準備できた時点で、改善措置の方法を変更する。