Affected vehicles
Hino Hino Profia 2010–2017
Hazard
In large tractor electrical wiring, waterproofing at the branch points of electric cab tilt and air conditioning wiring is inadequate, allowing water ingress at the branch points. This causes corrosion and breakage of the wire strands. As a result, the electric cab tilt and air conditioning may become inoperative, and in worst cases, the corroded area may overheat, risking burn-through of the wiring around the branch point.
Show original (日本語)
大型トラクタの電気配線において、電動キャブチルト及びエアコン用配線の分岐部の防水処理が不適切なため、分岐部より水が浸入し、素線が腐食して断線するものがある。そのため、電動キャブチルトやエアコンが作動しなくなり、最悪の場合、腐食部が発熱して、分岐部周辺が焼損するおそれがある。
Remedy
Replace the affected wiring with service replacement wiring on all vehicles. Additionally, inspect the affected wiring, and repair any damage found in the wiring around the branch points.
Show original (日本語)
全車両、当該配線を補修用配線に交換する。なお、当該配線を点検し、分岐部周辺の配線に損傷が認められる場合は、損傷部位を補修する。