Fire risk
Japan
Published 14 Jun 2019
Ref JP-1228540
Porsche: Electrical System - Other
Translated from Japanese · machine translation
- Country
- Japan
- Published
- 14 Jun 2019
- Units affected
- 3431
- Reference
- JP-1228540
Affected vehicles
Porsche Panamera 2010–2016
Porsche Panamera 4 2010–2016
Porsche Panamera 4S 2010–2016
Porsche Panamera GTS 2010–2016
Porsche Panamera S 2010–2016
Porsche Panamera S e-hybrid 2010–2016
Porsche Panamera Turbo 2010–2016
Porsche Panamera Turbo S 2010–2016
Porsche Panamera 2010–2016
Porsche Panamera 4 2010–2016
Porsche Panamera 4S 2010–2016
Porsche Panamera GTS 2010–2016
Porsche Panamera S 2010–2016
Porsche Panamera S Hybrid 2010–2016
Porsche Panamera Turbo 2010–2016
Porsche Panamera Turbo S 2010–2016
Hazard
Certain air conditioning blower control units have inadequate water resistance due to improper housing design. Water ingress into the unit can cause internal electrical wiring short circuits and circuit board burnout, potentially resulting in fire.
Show original (日本語)
エアコンブロアコントロールユニットにおいて、ハウジング形状が不適切なため、防水性が不十分なものがある。そのため、同ユニット内部に水分が浸入すると、内部の電気配線が短絡し基板が焼損して、最悪の場合、火災に至るおそれがある。
Remedy
Inspect all vehicles' air conditioning blower control unit part numbers. Replace units with affected part numbers with corrective units. Pending availability of corrective units, apply interim measures by adding a waterproof seal and power cutoff relay to the unit.
Show original (日本語)
全車両、エアコンブロアコントロールユニットの部品番号を点検し、交換対象の部品が装着されている場合には対策品に交換する。 なお、対策品の準備に時間を要するため、暫定対策として同ユニットに防水用のシールと電源遮断用のリレーを追加で組付ける。